Price
|
Call
|
Stock
|
Indent
|
|
Payment Term
|
DP
|
|
SPECIFICATION :
STYLE : Integral
In-Line Mass Flow Meter
SENSOR: Two
reference grade Platinum RTD clad in 316SS sheath
MATERIAL:
Wetted metal components: 316SS
POWER: 24VDC
Standard (12VDC or 115/230VAC optional)
POWER DISSIPATION:
<2.5 W
ELECTRONICS:
Microprocessor based (Hybrid-Digital)
ELECTRONICS
ENCLOSURE: Integral mount, NEMA 4 enclosure
DISPLAY: High
contrast photo-emissive OLED graphical display (Flow Rate, Totalizer,
Temperature)
TURNDOWN: 100
to 1
RESOLUTION: 1000
to 1
LOW END
SENSITIVITY: 5 SFPM
FIELD
CALIBRATION CHECK: Yes - Digital system allows raw signal validation
(milli-watts)
COMMUNICATIONS:
Modbus® compliant RS485 RTU or optional HART® communications
APPROVALS: CSA
C22.2 (24 VDC); ULI604, Class I, Div 2, Groups , C, D T4 (24VDC);
CE (AC Power or
24VDC)
FIELD
RECONFIGURABLE: Sage ADDRESSER required
FLOW ACCURACY:
+/- 0.5% of Full Scale +/- 1% of reading (Enhanced accuracy optionally
available with limited turn-down)
FLOW
REPEATABILITY: 0.2%
RESPONSE TIME:
1 second time constant
GAS TEMPERATURE
RANGE: Standard -40° to 200°F (93°C), Optional to 300°F (149°C) and 450°F
(232°C)
GAS PRESSURE:
500 PSIG (If higher pressure needed, contact Sage)
FLOW OUTPUT: 4
to 20 mA for Rate
TOTALIZER:
24VDC pulse for Totalized value
TEMPERATURE
OUTPUT: Through Modbus® only
AMBIENT
TEMPERATURE: -40° to 150°F (66°C)
FLOW BODY:
316SS Schedule 40 Flow Bodies sized from 1/4" x 6" long to 4" x
12" long.
Male NPT ends
standard (Flanges and other options available)
RELAYS: N/A
FLOW CONDITIONING:
Flow Conditioners are built in to In-Line Style Flow Bodies from 1/2" to
4"
ENCLOSURE
DEPTH: DC: 4.35" ; AC: 5.35"