ALIA ELECTROMAGNETIC FLOW METER
|
AMC2100E Series
|
|
AMC2100E series Converter With temperature/energy function can be used with AMF series flowmeter in both compact or separate versions. |
|
|
|
FEATURES
|
|
Four line LCD display Flowrate/Energy/Totalizer
Accuracy of +/-0.4% of reading
Bi-directional flow measurement, current and pulse output
Large digital display, With temperature/energy function
99 times records for power on/off
MODBUS/HART communication
|
|
SPECIFICATION
|
|
Excitation: |
Keyboard: |
Square wave |
4 keys from external for programming |
Display: |
and display control. |
4 lines LCD with backlight |
Low Flow Cutoff: |
Line 1 |
0 to 9.9 % |
Date and Time |
Datalogger Function: |
Line 2 |
99 times records for power on/off |
6 digit flowrate |
Record Data: |
7 digit energy value |
Date/Time when Power on/off |
Fault code |
99 years flow rate/energy/ |
Supply temperature |
Temperature / Total flow / Total energy |
Line 3 |
One Record Data per Hour |
9 digit totalizer for forwarding/ reverse flow |
Damping: |
9 digit totalizer for heat / cold energy |
0.1 to 99.9 Second |
Fault code content |
Self Diagnosis: |
Return temperature |
The following error message is |
Line 4 |
indicated during application |
Differential temperature |
– Coil fail |
Unit |
– Power fail |
L/S, L/M, L/H, M3/S, M3/L, M3/H |
– Output overaged |
KW, MW, KJ/H, MJ/H, GJ/H |
– Internal error |
Measuring Range: |
– Overflow |
Min. 0 to 0.15 m/s |
– Empty pipe |
Max. 0 to 15 m/s |
Cable Entry: |
Accuracy: |
PG11 |
+/-0.4% of reading (Velocity >= 0.5 m/s) |
Protection Class: |
+/-0.002 m/s (Velocity < 0.5 m/s) |
IP 65 |
Repeatability: |
Ambient Temperature: |
+/-0.1% of reading |
-25 to +65 oC |
Current Output: |
Material: |
4-20 mA (Isolated) |
Aluminum Alloy |
Load |
Temperature Input: |
Max. 600 ![](https://i0.wp.com/www.alia-inc.com/en/table/UploadFile/201041924343508.jpg) |
PT1000 , 2 wire |
Pulse output: |
Power Supply: |
Open collector |
90-260 VAC, 50/60 Hz |
Rating |
24 VDC +/- 10% (Option) |
3 to 30 VDC, 20 mA Max. |
Power Consumption: |
Pulse Rate: |
3-17 W (depending on the sensor size) |
1)Scale pulse, (Pulse/M3, Pulse/L,
Other) |
Weight: |
2)Frequency, 0-5000 Hz |
1.4 Kg |
Communication: |
Mounting: |
RS 485(MODBUS Protocol) |
Wall mounting |
HART signal |
Bracket on 2″ pipe |
Data Storage: |
|
Operation parameters and totalization |
|
figures are stored by EEPROM for more than 10 years |
|
|