KOBOLD NUS-4 Ultrasonic Level Meter
The Kobold ultrasonic level meter, model NUS-4, is used for non-contact, continuous level and volume measurement in vessels or for flow measurement in open channels.Level measurement technology based on the non-contacting ultrasonic principle is especially suited for applications where, for any reason, no physical contact can be established to the surface of the material to be measured.
Such reasons may include corrosive attack by the process medium against the measuring device material (acids), possible contamination (sewage) or particles of the process medium adhering to the measuring device (adhesive materials).
The ultrasonic level metering technology is based on the principle of measuring the time required for the ultrasound pulses to make a round trip from the sensor to the level to be measured and back. The sensor emits an ultrasonic pulse train and receives the echoes reflected. The electronic evaluates the echo time of the pulses and determines the level. The evaluating electronics are mounted compact on the unit.
For remote transmission, a norm signal output and for monitoring purposes, a relay contact is available. For programming and for local display, the units may be delivered with an optional pluggable programming unit with an LCD display.
The sensors have a total beam angle of 5°-7° at -3 dB. This ensures a reliable measurement in narrow silos with uneven side walls as well as in process tanks with various protruding objects. Furthermore, as a result of the narrow beam angle – the emitted ultrasonic signals have an outstanding focusing – deep penetration through gases, vapor and foam is ensure
Technical Details
Measuring principle: | the ultrasonic principle, echo time measurement | |
Beam cone: | NUS-4×04 : | 6° |
NUS-4×06; NUS-4×10 ; NUS-4×15 : | 5° | |
NUS-4×08 ; NUS-4×25 : | 7° | |
Delay time: | 10, 30, 60 seconds; programmable | |
Meas. accuracy (at 20 °C): | ±0.2 % of reading | |
+0.05 % of a full scale | ||
Resolution: (depending on measuring distance) | <2 m: 1 mm | |
2 … 5 m: 2 mm | ||
6 … 10 m: 5 mm | ||
>10 m: 10 mm | ||
Mounting position: | vertical to the product surface | |
Process temperature: | -30 … +90 °C | |
Ambient temperature: | -30 … +70 °C | |
-25 … +70 °C (with programming unit) | ||
Operating pressure: | 0.5 … 3 bar abs.(<1 bar abs. on request) | |
Materials | ||
Housing: | aluminum, powder-coated | |
Sensor and connection: | polypropylene, PVDF | |
Process connection: * G-thread with counter nut and EPDM-gasket | NUS-4×04: | G 1½*, 1½ NPT |
NUS-4×06, NUS-4×08: | G 2*, 2 NPT | |
NUS-4×10: | flange DN 80, ANSI 3″ | |
NUS-4×15: | flange DN 125, ANSI 5″ | |
NUS-4×25: | flange DN 150, ANSI 6″ | |
Electrical connection: | 2 x M 20 x 1,5 cable glandcable diameter 6 … 12 mmand 2 x ½” NPT | |
wire cross section:0.5 … 1.5 mm2 | ||
Switching output: | relay (SPDT) 30 VDC, 1A | |
Analog output: | 4 … 20 mA (3.9 … 20.5 mA)galvanically isolated, protection against surge transients | |
Load: | max. (Us – 11.4 V) / 0.02 A, | |
Power supply: | 12 – 36 VDC, 2-wire (reverse polarity protected) | |
Display (pluggable): | 6-digit LCD-display, symbols and bar graph, PBT, glass fiber reinforced, flameproof (DuPont®) | |
Protection: | sensor IP 68, Housing: IP 67 | |
Weight: | with thread : | approx. 1.1 kg |
with flange: | approx. 2.5 kg |
More info and price please contact marketing@wmablog.com