DESCRIPTION

ONICON F-3200 inline electromagnetic flow meters adalah flow meter yang cocok digunakan untuk mengukur flow rate cairan yang konduktif di berbagai macam jenis penggunaan. Flow meter magnetic F-3200 dapat diatur untuk mengeluarkan output analog untuk mengukur flow rate nya, maupun flow totalization dan komunikasi serialnya menggunakan jaringan RS485.


FEATURES
 
Exceptional Performance & Accuracy – 
F-3200 series inline meters deliver unmatched accuracy in installations with just three diameters of straight pipe upstream of the meter!

Easy to Install and Use – 
Every ONICON meter is individually wet calibrated and programmed for the application – saving start-up and commissioning time!

Excellent Long Term Reliability – 
ONICON electromagnetic flowmeters have no moving parts and employ state-of-the-art electronics, ensuring years of accurate, trouble-free performance.

Redundant Outputs – 
The F-3200 series inline meters can be ordered with an additional, redundant analog output. This optional feature can provide a cost-effective alternative in Mission Critical applications that require redundant flow measurements.

APPLICATIONS

• Chilled water, hot water, condenser water and water/
glycol/brine solutions used in HVAC
• Bi-directional flow for primary/secondary bypass
• Process flow with conductivity greater than 5 μS/cm
• Domestic/municipal water

CALIBRATION

Every ONICON F-3200 flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to international standards. A certificate of calibration accompanies every meter.

GENERAL SPECIFICATIONS

ACCURACY
± 0.2% of reading from 1.6 to 33 ft/s
± 0.0033 ft/s at flow rates < 1.6 ft/s

SENSING METHOD
Electromagnetic sensing (no moving parts)

FLUID TEMPERATURE RANGE
Refer to Liner Selection Table below

OUTER BODY MATERIALS OPTIONS
Carbon Steel painted Stainless Steel

FLOW TUBE (Internal)
304 Stainless Steel

CONNECTION TYPES AVAILABLE
Wafer
ANSI Class 150 flange
ANSI Class 300 flange

ELECTRICAL CONNECTIONS
Removable terminal blocks, for use with 18-22 AWG
shielded cable

FLUID CONDUCTIVITY
5 μS/cm minimum

POWER SUPPLY
Low Power, 24 VAC/DC, 12 VA typical
High Power, 120 – 240 VAC, 12 VA typical

DISPLAY
Backlit 16-character, 8-line graphic LCD displays: flow rate and velocity, flow direction and totals, short term data and error messages

OUTPUT SIGNALS
• Isolated 4-20 mA analog output for flow rate
• Two (2) isolated programmable digital/pulse outputs (configurable for flow frequency, pulse, alarm or flow direction)
• MODBUS® RTU (RS485)
• Redundant output with second isolated analog output for flow rate and two additional isolated programmable pulse outputs

ELECTRONICS ENCLOSURE
• Epoxy painted aluminum housing, NEMA 4 (IP67)
• Remote mount, a maximum distance from the sensor
– up to 325 ft at conductivities ≥ 200 μS/cm