DESCRIPTION
ONICON’s F-5500 Series Thermal Mass Flow
Meters mampu memberikan pengukuran flow yang akurat untuk material
natural gas, udara bertekanan tinggi, dan industrial gas lainnya. Desain
perangkat sensor mengukur mass flow secara langsung dan tidak
membutuhkan tambahan tekanan atau kompensasi suhu dalam penggunaannya.
APPLICATIONS
Accurate sub-metering of natural gas & propane for:
- Tenant space usage
- Boiler efficiency
- Campus monitoring
Also ideal for monitoring:
- Compressed Air
- Medical gases
- Other industrial gases
GENERAL SPECIFICATIONS
FLOW ACCURACY
Natural Gas / Propane Gas
± 1.0% of reading from 500 – 7000 SFPM
± 2.0% of reading from 100 – 500 SFPM
Compressed Air & other high-velocity calibrations
± 1.0% of reading + 0.5% of scale over a 100:1
turndown
TEMPERATURE ACCURACY
± 1.0°F over the range of -40 to 250° F
OVERALL FLOW RANGE
15 to 35,000 SFPM
OPERATING RANGE FOR COMMON PIPE SIZES15 to 7000 SFPM in schedule 40 pipePipe Size (Inches) | Flow Rate (SCFH) | |||
Min | Max | |||
¾ | 3.3 | 1,560 | ||
1 | 5.4 | 2,521 | ||
1¼ | 9.3 | 4,362 | ||
1½ | 13 | 5,938 | ||
2 | 21 | 9,740 | ||
2½ | 30 | 13,964 | ||
3 | 46 | 21,562 | ||
4 | 80 | 37,130 | ||
5 | 125 | 58,350 | ||
6 | 181 | 84,263 | ||
8 | 313 | 145,912 |
FEATURES
BACnet MS/TP or MODBUS RTU –
The standard F-5500 includes an RS485
output that provides BACnet MS/TP or Modbus RTU. Data reported to the
network includes flow rate and total, temperature
and elapsed time since reset.
User-Friendly Interface / Display –
The bright, easy-to-read, backlit display
and intuitive menu structure simplify page navigation and allow for
field programming. Free utility software is also available for
programming
and data logging.
Provides for Field Validation of Calibration –
F-5500 internal diagnostic functions
include a zero flow calibration check. This fast, easy to perform, the
test allows for field validation of the factory zero flow calibration.
The utility software provided with the meter allows you to print a
certificate validating the test results. Insertion Meters Can Be
Installed Without Interrupting
Gas Service* –
ONICON’s hot tap design allows for
installation without interruption to the gas service. The meter can also
be removed for service without disrupting the flow.
Highly Accurate Over a Wide Operating Range –
Our proprietary direct digital control
sensing circuitry is very stable yet highly responsive to changes
inflow. This design allows for accurate flow measurement over a very
wide operating range (over 1000:1 for the inline version). It also makes
the meter ideal for measuring low flow rates.
Excellent Value –
ONICON insertion style meters are accurate,
easy-to-use and reliable. They are also priced independently of
pipe size. This makes them an excellent value, particularly in larger
diameter pipes.
CALIBRATION
Every ONICON flow meter is wet calibrated
in a flow laboratory against standards that are directly traceable
to NIST. A certificate of calibration accompanies every meter.
* Installations must comply with federal,
state and municipal building codes. Review all proposed combustible gas
installations with your local code enforcement officials before
attempting any installation.
METHOD
Thermal mass flow utilizing direct digital control sensing circuitry
PIPE SIZE RANGE
Insertion style – 1½” through 24” nominal diameter
Inline style – ¾” through 6” nominal diameter
INPUT POWER
12 – 28 VDC, 6W minimum power
FLUID TEMPERATURE RANGE
-40° F to 250° F
AMBIENT TEMPERATURE RANGE
-40° F to 158° F
MAXIMUM OPERATING PRESSURE
Insertion flow meter:
Standard process adapter fitting – 60 PSIG (4.1 barg) max
High-pressure adapter fitting – 150 PSIG (10.3 barg) max
Inline flow meter:
Flanged-ANSI 150 (230 PSIG at 100˚ F (16 barg))
NPT 300 PSIG (20.7 barg)
All stainless steel ferrules
PRESSURE DROP (@ 2500 SFPM, 70° F, and 2 PSIG)
Insertion meter – Less than 0.5” W.C. (H20) in 1½” diameter
pipes, decreasing in larger pipes
Inline meter – (with built-in flow conditioner)
Less than 0.5” W.C (H20) in 2” and larger diameter meters
Less than 0.9” W.C (H20) in 1” and 1½” diameter meters
PROGRAMMING / MEMORY
Factory programmed for specific
applications. Field programming available through the user interface or
mini-USB interface and utility program. Non-volatile memory retains all
program parameters and totalized values in the event of power loss.
OUTPUT SIGNALS PROVIDED
Analog outputs: 4-20 mA (standard on all models) Select from one of the following options as the second
output:
- RS485 interface: BACnet MS/TP or Modbus RTU
(field selectable)
- Programmable pulse output: Field selectable as scaled
pulse or alarm (Isolated open collector output)
- 4-20 mA with HART FSK (Only available with
programmable pulse output)
MATERIAL
Wetted metal components: 316 stainless steel
ELECTRICAL CONNECTIONS
Enclosed terminal blocks, cable access through two ¾” NPT
conduit fittings
APPROVALS
FM (USA) FMc (CAN): Approved
Class 1, Div 1, Groups B, C, D;
Class 2, Div 2, Groups E, F, G;
Class 3, Div 1; T4, Ta = -40˚ C to 70˚ C;
Class 1, Zone 1, AEx/Ex db IIB + H2 T4;
Gb Ta = -40˚ C to 70˚ C;
Type 4X, IP66/67
CE Mark
EMC Directive; 2014/30/EU
Emissions and Immunity Testing:
EN61326-1:2013
Massachusetts Board of State Examiners of Plumbers and Gasfitters