Home » » Vortex Flow Meter

Vortex Flow Meter

Flow Meter
Vortex Flow Meter
FV Vortex flow meter measure volume/mass flow of liquids, gases and steam. Application is water supply, industry circulation, sewage treatment, oil, chemical reagents, compressed air, saturated or overheated steam, natural gas and other media.
 
Vortex steam Temperature compensation flow meter
SPECIFICATION
  • Meter size: DN 15 – 300
  • Accuracy  :  ± 0.5%
  • Temperature:  120 ℃ , 180 ℃ , 250 ℃ , 350 ℃  ( option)
  • Pressure: 16 bar, 24 bar, 40 bar
  • High Vibration Resistance
  • Protection to total flow with EEPROM
  • Power: Lithium Battery (4-5 years )
 

RANGE CHART

Size
Liquid
Gas
Flow
Frequency
Flow
Frequency
(m3/h)
(Hz)
(m3/h)
(Hz)
20
1 ~ 10
40~396
5.5~50
218~1982
25
1.6 ~ 16
32~325
8.5~70
172~1420
40
2.5 ~ 25
13~130
22~220
115~1147
50
3.5 ~ 35
9~93
36~320
96~854
65
6.5 ~ 68
8~82
50~480
61~583
80
10 ~ 100
6~65
70~640
45~417
100
15 ~ 150
5~50
130~1100
43~367
125
27 ~ 275
5~47
200~1700
33~290
150
40 ~ 400
4~40
280~2240
27~221
200
80 ~ 800
3~33
580~4960
24~207
250
120 ~ 1200
3~26
970~8000
20~171
300
180 ~ 1800
2~22
1380~11000
17~136

 

Drawing

Size
Standard
H
L
LO
D1
D2
15
F 19 X 1.5
290
116
80
68
135
20
F 26 X 3
290
116
80
68
135
25
F 32 X 3.5
290
116
80
68
135
32
F   39 × 3.5
290
116
80
68
135
40
F 49 × 4.5
295
120
80
80
140
50
F 59 X 4.5
300
124
80
88
145
65
F 74 X 4.5
308
128
80
105
165
80
F 89X 4.5
315
128
80
120
180
100
F 109 X 4.5
328
132
80
148
210
125
F 133 X 4.5
340
137
85
174
235
150
F 159 X 4.5
351
146
90
196
270
200
F 219 X 9
378
169
105
250
325
250
F 273 X 11
402
184
120
300
375
300
F 325 X 12
428
199
135
350
425






More info and price please contact marketing@wmablog.com