Alia Vortex Flow Meter | Gas Flow Meter
Flow Meter Gas
ALIAVTX AVF7000 is a Vortex Flowmeter
based on the Von Karman theory of vortices generated by a bluff body in
the pipe. The number of vortices is linearly proportional to the
volumetric flow in the pipe
The AVF7000 is a versatile flowmeter
widely used for Gases, Steam & Liquid applications. There are no
moving parts and comes with either Flange or wafer connection.
The
standard configuration has a local indication for flow rate and total
flow as well as a 4-20mA output functions. The microprocessor design can
filter out erroneous signals as well as interference caused by pipe
vibration.
FEATURES
- Simplified setup and self-diagnostic functions
- Auto. Temperature & Pressure compensation
- 4-20 mA and pulse outputs, user-selectable
- a very wide selection of sizes
- Wide temperature range which can up to 420 Deg. C
- Non-volatile memory for setup and calibration
SPECIFICATION
|
|
| Size: |
Local display: |
| 10,15,20,25,32,40,50,65,80,100,125,150 |
4 lines LCD |
| 200,250,300,350,400,450,500mm |
4 digit flowrate |
| Measuring Range: |
8 digit Totalizer |
| Steam – 1.6 to 540,000 Kg/Hr |
Current output: |
| Gas – 3 to 46,000 M3/Hr |
4-20 mA (2 wire) |
| Liquid – 0.3 to 4950 M3/Hr |
Load |
| Material: |
600 Ohm |
| Stainless Steel 301 / 304 / 316 |
Pulse output: |
| Accuracy: |
Scale Pulse(3 wire) |
| Liquid |
Rating |
| +/-0.7% value of reading |
3 to 30VDC, 20mA Max. |
| Gas & Steam |
Communication: |
| +/-1.0% value of reading |
RS485 |
| Repeatability: |
Data storage: |
| +/-0.2% value of reading |
Operation Parameter and Totalizer |
| Process Connection: |
Figures are stored by EEPROM for more |
| Flange / Wafer |
than 10 years |
| Flanges type |
Housing Material: |
| JIS 10K / JIS 20K / JIS 40K |
Aluminum Alloy |
| ANSI 150# / ANSI 300# / ANSI 600# |
Cable Entry: |
| DIN PIN 10 / PN 16 / PN25 / PN 40 |
2 X M20 *1.5 |
| Wafer type |
Power supply: |
| DN40~DN250 |
12-36 VDC |
| without Temperature / Pressure Sensor |
Ni-MH Battery(3 years working Hours) |
| Temperature: |
Key Pad: |
| -40 ~ +280 Deg. C (Standard) |
4 keys from internal for Programming |
| -40 ~ +420 Deg. C (Optional) |
and display control |
| Ambient Temperature: |
Option: |
| -20 ~ +60 Deg. C |
Pressure Sensor |
| Pressure: |
Pressure compensation |
| 78 Kg/cm2 (Max.) |
Signal output |
| Protection: |
0-30 mV DC(20 uA Power supply) |
| IP 65 |
Temperature sensor |
| Explosion Proof, Exd IIC T6 |
Temperature compensation |
| Intrinsically Safe, Ex ia IIC T4 |
Signal output |
|
PT100 ohm (3 wires) |
|