Alia Vortex Flow Meter | Steam Vortex Flow Meter | Steam Flow Meter
Alia Steam Flow Meter
ALIAVTX AVF7000 is a Vortex Flowmeter
based on Von Karman theory of vortices generated by a bluff body in the
pipe. The number of vortices are linearly proportional to the
volumetric flow in the pipe.
The AVF7000 flow meters are versatile flowmeter
widely used for Gases, Steam & Liquid applications. There are no
moving parts and comes with either Flange or wafer connection.
The
standard configuration has a local indication for flow rate and total
flow as well as a 4-20mA output functions. The microprocessor design can
filter out erroneous signals as well as interference caused by pipe
vibration.
Features
- Simplified setup and self-diagnostic functions
- Auto. Temperature & Pressure compensation
- 4-20 mA and pulse outputs, user-selectable
- a very wide selection of sizes
- Wide temperature range which can up to 420 Deg. C
- Non-volatile memory for setup and calibration
SPECIFICATION
|
|
Size: |
Local display: |
10,15,20,25,32,40,50,65,80,100,125,150 |
4 lines LCD |
200,250,300,350,400,450,500mm |
4 digit flowrate |
Measuring Range: |
8 digit Totalizer |
Steam – 1.6 to 540,000 Kg/Hr |
Current output: |
Gas – 3 to 46,000 M3/Hr |
4-20 mA (2 wire) |
Liquid – 0.3 to 4950 M3/Hr |
Load |
Material: |
600 Ohm |
Stainless Steel 301 / 304 / 316 |
Pulse output: |
Accuracy: |
Scale Pulse(3 wire) |
Liquid |
Rating |
+/-0.7% value of reading |
3 to 30VDC, 20mA Max. |
Gas & Steam |
Communication: |
+/-1.0% value of reading |
RS485 |
Repeatability: |
Data storage: |
+/-0.2% value of reading |
Operation Parameter and Totalizer |
Process Connection: |
Figures are stored by EEPROM for more |
Flange / Wafer |
than 10 years |
Flanges type |
Housing Material: |
JIS 10K / JIS 20K / JIS 40K |
Aluminum Alloy |
ANSI 150# / ANSI 300# / ANSI 600# |
Cable Entry: |
DIN PIN 10 / PN 16 / PN25 / PN 40 |
2 X M20 *1.5 |
Wafer type |
Power supply: |
DN40~DN250 |
12-36 VDC |
without Temperature / Pressure Sensor |
Ni-MH Battery(3 years working Hours) |
Temperature: |
Key Pad: |
-40 ~ +280 Deg. C (Standard) |
4 keys from internal for Programming |
-40 ~ +420 Deg. C (Optional) |
and display control |
Ambient Temperature: |
Option:
|
|
-20 ~ +60 Deg. C
Pressure Sensor
Pressure compensation
|
78 Kg/cm2 (Max.) |
Signal output |
Protection: |
0-30 mV DC(20 uA Power supply) |
IP 65 |
Temperature sensor |
Explosion Proof, Exd IIC T6 |
Temperature compensation |
Intrinsically Safe, Eex ia IIC T4 |
Signal output |
|
PT100 ohm (3 wires) |